
Løsning, Denmark
Inductive components, engineered to IEC and UL standard.
ICD&C designs high- and low-frequency transformers and reactors for industrial and institutional infrastructure — from spec through production, with manufacturing partners across Europe and China.
IEC / ULDesign standard
200 VA – 31.5 MVAPower range
EU + CNProduction sitesPRIMARYSECONDARY
About ICD&C
A design office and sales.
We’re a team of design engineers building inductive components — transformers and reactors, conventional and planar — for clients running industrial and institutional infrastructure projects.
Every project gets full technical support from spec to delivery, with our own engineers staying close to your electronics team throughout, not a handoff to a black box overseas.
- 01 Design of inductive components and production specs for HF/LF transformers and reactors, per IEC/UL.
- 02 Project and production management aligned to IEC, UL and ETL standards.
- 03 Electronics design collaboration and European production.
- 04 Project management run jointly with the client, end to end.
- 05 Production and sourcing management through China manufacturing partners.
Product Range
Eight product families, from 200 VA transformers to 31.5 MVA oil-immersed units ToroidalSingle-PhaseThree-PhaseAC ReactorsPhase-Shift RectifierDry-Type (MV)Oil-Immersed HF Inductors
TOROIDAL — 135 SERIES
Toroidal safety transformer
- Power range 200 – 5000 VA
- Primary Dual 115/230V, 50/60Hz
- Insulation Class F (155°C), 4000Vrms
- Standard UL506, EN60950 / EN60065
SINGLE-PHASE
Single-phase isolating transformer
- Power range0.5 – 315 kVA
- Build Open or enclosed, IP00 / IP23
- Insulation Class F (155°C), H on request
- Standard IEC61558-2-4, IEC60726/60076
THREE-PHASE
Open three-phase transformer, IP00
- Power range0.25 – 2000 kVA
- Vector group Dyn11 standard, Dyn5/Ynd1/Ynd5
- Insulation B up to 30 kVA; F std / H opt. above 40 kVA
- Standard EN61558-2-4; IEC60726/IEC60076 above 40 kVA
AC REACTORS
Three-phase harmonic AC reactor
- Reactive power5 – 50 kVAr
- StandardIEC 60289 / 60076
PHASE-SHIFT RECTIFIER
Dry-type phase-shift rectifier transformer
- Power rangeUp to 15,000 kVA
- Voltage classUp to 35 kV
- Build Dry type
- Typical use Petrochemical, metallurgy, rolling mills
DRY-TYPE (MV)
Epoxy resin cast dry-type transformer
- Power rangeUp to 6,300 kVA
- Voltage classUp to 35 kV
- Build Epoxy resin cast winding
- Typical use High-rises, airports, subways, data-critical sites
OIL-IMMERSED
Oil-immersed distribution transformer
- Power rangeUp to 31,500 kVA
- Voltage classUp to 35 kV
- Build Oil-immersed
- Typical use Industrial, mining, utility distribution
HF INDUCTORS
High-power inductors for high-frequency electronics
- Frequency range 10 kHz – 500 kHz+
- Winding Litz-wire or foil, high RMS/ripple current
- Core Ferrite, amorphous or powder, gapped
- Cooling Forced-air or conduction
Custom Design
Not on the list? We’ll design it.
Standard catalog types cover most jobs, but a lot of our work starts from a blank spec sheet — a voltage, frequency or footprint the catalog doesn’t have. Our engineers take it from there: core selection, winding layout, insulation class and mechanical mounting, built around your application rather than a datasheet.
Every custom design goes through the same IEC/UL verification as our standard range, with a prototype signed off before production starts.
- 01 Spec review — voltage, frequency, power, mounting and target standard.
- 02 Design — core, winding and insulation chosen for the application, not a template.
- 03 Prototype and test — verified against IEC/UL before production is approved.
- 04 Production — run through our Europe and China manufacturing partners.
Ermedin Halilovic
Experienced Design Engineer — Inductors, IEC, Analog Circuit Design, Power Supplies, Hardware Architecture
Experienced designer with a demonstrated history of working in the electrical and electronic manufacturing industry. Skilled in inductors, IEC standards, analog circuit design, power supplies, and hardware architecture.
As an experienced design engineer, I offer a range of engineering services for various industrial and institutional infrastructure projects. My specialty lies in leading the design and delivery of inductive components, obtaining UL/IEC approvals, and ensuring compliance with ISO 9001 standards while collaborating closely with customers to address their specific needs.
I have successfully fostered collaborations with customers in multiple electrotechnical sectors, enhancing their experience and satisfaction. Additionally, I have overseen quality management processes, conducted external audits, and ensured operational excellence in global companies.
In my role as a Transformer Lead Engineer at Vestas Wind Systems A/S, I was responsible for managing the transformer room for the V164 wind turbine type in Århus. I collaborated with suppliers on transformer product development for new wind turbine versions, addressing concessions and deficiencies to support subject matter experts in high-voltage equipment. My focus was on ensuring the smooth operation and maintenance of transformers to optimize turbine performance.
Furthermore, I was a member of the International Electrotechnical Commission TC96 Transformer Committee, where I maintain all publications under TC 96’s responsibility and revise IEC 60989 for inclusion in the IEC 61558 series.
I have designed inductive components over the last 40 years for both high-frequency and low-frequency applications across various industrial sectors, accommodating both small and high-volume production. I have also evaluated alternative components for a 7MVA converter and designed control panel systems, focusing on simplifying complex solutions.
By implementing innovative strategies, I have optimized system efficiency and functionality, collaborating with cross-functional teams to ensure seamless integration of control panel systems and achieving cost-effective solutions without compromising high-quality standards.
Get in touch
Start a spec conversation.
Send us your requirements — power, frequency, core preference, target standard — and we’ll scope design and production together.
EMAIL info@admin
PHONE +45 50 50 69 83
ADDRESS Bottrupvej 5, 8723 Løsning, Denmark
VAT / CVR DK30437926
© 2026 ICD&C Design of inductive components — HF/LF, IEC/UL
