HPV power inductor · 800 V

HPV030-15-132 · 1,300 µH, 30 A power inductor for 800 V, 15 kHz

Powder-core toroidal power inductor with Litz winding and flying leads for 12.7 kW boost and buck stages on an 800 V DC bus at 15 kHz.

Standard series · HPV (800 V)

Preliminary · design data

HPV030-15-132

1,300 µHInductance ±8 %, 10 kHz / 1 V
30 A rmsRated current, 15 kHz incl. ripple
50 ASaturation current (L ≥ 80 %)
12.7 kWPower at Vbus ≤ 847 V (D = 0.5)
42 KTemperature rise, Ta 50 °C, still air
≈ 4.5 kgWeight approx.

Electrical characteristics

ParameterConditionValue
Construction–Single unit
Inductance L010 kHz, 1 V, 0 A DC1,300 µH ±8 %
Rated current Irms15 kHz, ripple incl., Ta ≤ 85 °C, natural convection30 A
Saturation current IsatL ≥ 80 % of nominal L050 A
Ripple currentat 15 kHz, 800 V, D = 0.5 (design basis)12 A pk-pk
Switching frequencydesign frequency15 kHz
DC resistance25 °C, 4-wire26.2 mΩ typ.
Power lossrated current, Ta 50 °C47 W typ.
Temperature riserated current, Ta 50 °C, still air42 K typ.
Operating ambientat rated current−40 … +85 °C
Insulation classwinding systemF (155 °C)
Power rating / max. bus voltageD = 0.5 (buck / boost), design ripple; P ≈ ½ · Vbus · Irms12.7 kW at Vbus ≤ 847 V

Mechanical

Outer diameter (per unit)≤ 145 mm
Height (per unit)≤ 61 mm
Free inner bore≥ 54 mm
Weight≈ 4.5 kg
TerminationFlying leads, stripped and solder-tinned
CoreDistributed-gap powder toroid, coated
MountingAluminium L-bracket or base plate (on request)

Same rating, other frequencies

Neighbouring ratings (15 kHz)

Preliminary design data – typical values to be confirmed on first samples. Bracket mounting, aluminium winding and forced-air ratings on request. Specifications subject to change without notice.

Next step

Send us your spec.